SABS approved Aerial Bundled ABC Cable for Overhead Use Power Cable
1. Applications
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.
2. Construction
Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand Aac, ACSR, or 6201 alloy neutral messenger.
3. Standards
ASTM B-230, B-231, B-232 and B-399, ICEA S-76-474
4. The Diagram of Structure:
NOTE: Designated Sized are ACSR 6/1 Diameter Equivalent Resistivity Per ASTM-B-399 for 6201.
Conductor temperature of 75° C; Ambient temperatures of 40° C; Emissivity 0.9; 2ft/sec. Wind in sun. Packaging: Available in 500ft coils and in long lengths on reels.
The data is approximate and subject to normal manufacturing tolerances.
To determine current ampacity by conductor size, please consult The National Electric Code, latest edition
Specification:
(1)Self-supporting |
 |
 |
 |
Phase |
Phase |
Phase |
Approx.Overall Diameter |
Min.Bending Radius |
Max. D.C. Resistance of Conductor at 20 |
 |
 |
 |
AAC+UV-XLPE |
Compact Conductor |
UV-XLPE Insulation |
 |
 |
 |
No.X Normal Cross Section of Cores |
No.of Al Wires |
Overall Diameter |
Thickness |
Min. |
Diameter |
 |
 |
 |
No. X mm 2 |
- |
mm |
mm |
mm |
mm |
mm |
kN |
ohm/km |
 |
 |
 |
4 X 16 |
7 |
4.8 |
1.2 |
0.98 |
7.2 |
17.42 |
2.07 |
1.91 |
 |
 |
 |
4 X 25 |
7 |
6 |
1.4 |
1.16 |
8.8 |
21.3 |
3.3 |
1.2 |
 |
 |
 |
4 X 35 |
7 |
7 |
1.6 |
1.34 |
10.2 |
24.68 |
4.5 |
0.868 |
 |
 |
 |
4 X 50 |
7 |
8.3 |
1.6 |
1.34 |
11.5 |
27.83 |
6.2 |
0.641 |
 |
 |
 |
4 X 70 |
19 |
10 |
1.8 |
1.52 |
13.6 |
32.91 |
8.9 |
0.443 |
 |
 |
 |
4 X 95 |
19 |
11.6 |
1.8 |
1.52 |
15.2 |
36.78 |
12.3 |
0.32 |
 |
 |
 |
4 X 120 |
19 |
13 |
1.8 |
1.52 |
16.6 |
40.17 |
15.6 |
0.253 |
 |
 |
 |
4 X 150 |
19 |
14.6 |
1.8 |
1.52 |
18.2 |
44.04 |
19.2 |
0.206 |
 |
 |
 |
3 X 16 |
7 |
4.8 |
1.2 |
0.98 |
7.2 |
15.55 |
2.07 |
1.91 |
 |
 |
 |
3 X 25 |
7 |
6 |
1.4 |
1.16 |
8.8 |
19.01 |
3.3 |
1.2 |
 |
 |
 |
3 X 35 |
7 |
7 |
1.6 |
1.34 |
10.2 |
22.03 |
4.5 |
0.868 |
 |
 |
 |
3 X 50 |
7 |
8.3 |
1.6 |
1.34 |
11.5 |
24.84 |
6.2 |
0.641 |
 |
 |
 |
3 X 70 |
19 |
10 |
1.8 |
1.52 |
13.6 |
29.38 |
8.9 |
0.443 |
 |
 |
 |
3 X 95 |
19 |
11.6 |
1.8 |
1.52 |
15.2 |
32.83 |
12.3 |
0.32 |
 |
 |
 |
3 X 120 |
19 |
13 |
1.8 |
1.52 |
16.6 |
35.86 |
15.6 |
0.253 |
 |
 |
 |
3 X 150 |
19 |
14.6 |
1.8 |
1.52 |
18.2 |
39.31 |
19.2 |
0.206 |
 |
 |
 |
2 X 16 |
7 |
4.8 |
1.2 |
0.98 |
7.2 |
14.4 |
2.07 |
1.91 |
 |
 |
 |
2 X 25 |
7 |
6 |
1.4 |
1.16 |
8.8 |
17.6 |
3.3 |
1.2 |
 |
 |
 |
2 X 35 |
7 |
7 |
1.6 |
1.34 |
10.2 |
20.4 |
4.5 |
0.868 |
 |
 |
 |
2 X 50 |
7 |
8.3 |
1.6 |
1.34 |
11.5 |
23 |
6.2 |
0.641 |
 |
 |
 |
2 X 70 |
19 |
10 |
1.8 |
1.52 |
13.6 |
27.2 |
8.9 |
0.443 |
 |
 |
 |
2 X 95 |
19 |
11.6 |
1.8 |
1.52 |
15.2 |
30.4 |
12.3 |
0.32 |
 |
 |
 |
2 X 120 |
19 |
13 |
1.8 |
1.52 |
16.6 |
33.2 |
15.6 |
0.253 |
 |
 |
 |
2 X 150 |
19 |
14.6 |
1.8 |
1.52 |
18.2 |
36.4 |
19.2 |
0.206 |
 |
 |
 |
1 X 16 |
7 |
4.8 |
1.2 |
0.98 |
7.2 |
7.2 |
2.07 |
1.91 |
 |
 |
 |
1 X 25 |
7 |
6 |
1.4 |
1.16 |
8.8 |
8.8 |
3.3 |
1.2 |
 |
 |
 |
1 X 35 |
7 |
7 |
1.6 |
1.34 |
10.2 |
10.2 |
4.5 |
0.868 |
 |
 |
 |
1 X 50 |
7 |
8.3 |
1.6 |
1.34 |
11.5 |
11.5 |
6.2 |
0.641 |
 |
 |
 |
1 X 70 |
19 |
10 |
1.8 |
1.52 |
13.6 |
13.6 |
8.9 |
0.443 |
 |
 |
 |
1 X 95 |
19 |
11.6 |
1.8 |
1.52 |
15.2 |
15.2 |
12.3 |
0.32 |
 |
 |
 |
1 X 120 |
19 |
13.01 |
1.8 |
1.52 |
16.6 |
16.6 |
15.6 |
0.253 |
 |
 |
 |
1 X 150 |
19 |
14.6 |
1.8 |
1.52 |
18.2 |
18.2 |
19.2 |
0.206 |
 |
 |
 |
(2) Phase + Supporting |
 |
 |
 |
Phase |
Supporting |
Phase |
Supporting |
Approx. Overall Diameter |
 |
 |
 |
 |
AAC+UV-XLPE |
AAAC+UV-XLPE |
Compact Conductor |
UV-XLPE Insulation |
Conductor |
UV-XLPE Insulation |
 |
 |
 |
 |
No.X Normal Cross Section of Cores |
No.X Normal Cross Section of Cores |
No.of Al Wires |
Overall Diameter |
Normal Thickness |
No./Dia.of Al. Wire |
Normal Thickness |
 |
 |
 |
 |
No. X mm 2 |
No. X mm 2 |
- |
mm |
mm |
No./mm |
mm |
mm |
 |
 |
 |
 |
3 X 16 |
1 X 54.6 |
7 |
4.8 |
1.2 |
7/3.15 |
1.6 |
20.72 |
 |
 |
 |
 |
3 X 25 |
1 X 54.6 |
7 |
6 |
1.4 |
7/3.15 |
1.6 |
23.63 |
 |
 |
 |
 |
3 X 35 |
1 X 54.6 |
7 |
7 |
1.6 |
7/3.15 |
1.6 |
26.17 |
 |
 |
 |
 |
3 X 50 |
1 X 54.6 |
7 |
8.3 |
1.6 |
7/3.15 |
1.6 |
28.53 |
 |
 |
 |
 |
3 X 70 |
1 X 54.6 |
19 |
10 |
1.8 |
7/3.15 |
1.6 |
32.34 |
 |
 |
 |
 |
3 X 95 |
1 X 54.6 |
19 |
11.6 |
1.8 |
7/3.15 |
1.6 |
35.24 |
 |
 |
 |
 |
3 X 120 |
1 X 54.6 |
19 |
13 |
1.8 |
7/3.15 |
1.6 |
37.78 |
 |
 |
 |
 |
3 X 150 |
1 X 54.6 |
19 |
14.6 |
1.8 |
7/3.15 |
1.6 |
40.69 |
 |
 |
 |
 |
3 X 16 |
1 X 70 |
7 |
4.8 |
1.2 |
7/3.5 |
1.6 |
21.36 |
 |
 |
 |
 |
3 X 25 |
1 X 70 |
7 |
6 |
1.4 |
7/3.5 |
1.6 |
24.26 |
 |
 |
 |
 |
3 X 35 |
1 X 70 |
7 |
7 |
1.6 |
7/3.5 |
1.6 |
26.8 |
 |
 |
 |
 |
3 X 50 |
1 X 70 |
7 |
8.3 |
1.6 |
7/3.5 |
1.6 |
29.16 |
 |
 |
 |
 |
3 X 70 |
1 X 70 |
19 |
10 |
1.8 |
7/3.5 |
1.6 |
32.97 |
 |
 |
 |
 |
3 X 95 |
1 X 70 |
19 |
11.6 |
1.8 |
7/3.5 |
1.6 |
35.88 |
 |
 |
 |
 |
3 X 120 |
1 X 70 |
19 |
13 |
1.8 |
7/3.5 |
1.6 |
38.42 |
 |
 |
 |
 |
3 X 150 |
1 X 70 |
19 |
14.6 |
1.8 |
7/3.5 |
1.6 |
41.32 |
 |
 |
 |
 |
3) Phase+Supporting+ Service Connection |
 |
 |
 |
 |
Phase |
Supporting |
Service Connection |
Phase |
   Supporting |
Service Connection |
Approx.Overall Diameter of Bundled Cable |
AAC+UV-XLPE |
AAAC+UV-XLPE |
AAC+UV-XLPE |
Compact Conductor |
UV-XLPE |
Conductor |
UV-XLPE |
Compact Conductor |
UV-XLPE |
No.X Normal Cross Section of Cores |
No.X Normal Cross Section of Cores |
No.X Normal Cross Section of Cores |
No.of Al.Wire |
Overall Dia. |
Normal |
No./Dia.of Al. Wire |
Normal |
No. of Al. Wire |
Overall Dia. |
Normal |
Thickness |
Thickness |
Thickness |
No. X mm 2 |
No. X mm 2 |
No. X mm 2 |
- |
mm |
mm |
No./mm |
mm |
- |
mm |
mm |
mm |
3 X 16 |
1 X 54.6 |
1 X 25 |
7 |
4.8 |
1.2 |
7/3.15 |
1.6 |
7 |
6 |
1.4 |
27.05 |
3 X 25 |
1 X 54.6 |
1 X 25 |
7 |
6 |
1.4 |
7/3.15 |
1.6 |
7 |
6 |
1.4 |
30.25 |
3 X 35 |
1 X 54.6 |
1 X 25 |
7 |
7 |
1.6 |
7/3.15 |
1.6 |
7 |
6 |
1.4 |
33.05 |
3 X 50 |
1 X 54.6 |
1 X 25 |
7 |
8.3 |
1.6 |
7/3.15 |
1.6 |
7 |
6 |
1.4 |
35.65 |
3 X 70 |
1 X 54.6 |
1 X 25 |
19 |
10 |
1.8 |
7/3.15 |
1.6 |
7 |
6 |
1.4 |
39.85 |
3 X 95 |
1 X 54.6 |
1 X 25 |
19 |
11.6 |
1.8 |
7/3.15 |
1.6 |
7 |
6 |
1.4 |
43.05 |
3 X 120 |
1 X 54.6 |
1 X 25 |
19 |
13 |
1.8 |
7/3.15 |
1.6 |
7 |
6 |
1.4 |
45.85 |
3 X 150 |
1 X 54.6 |
1 X 25 |
19 |
14.6 |
1.8 |
7/3.15 |
1.6 |
7 |
6 |
1.4 |
49.05 |
3 X 16 |
1 X 54.6 |
 2 X 25 |
7 |
4.8 |
1.2 |
7/3.15 |
1.6 |
7 |
6 |
1.4 |
27.05 |
3 X 25 |
1 X 54.6 |
 2 X 25 |
7 |
6 |
1.4 |
7/3.15 |
1.6 |
7 |
6 |
1.4 |
30.25 |
3 X 35 |
1 X 54.6 |
 2 X 25 |
7 |
7 |
1.6 |
7/3.15 |
1.6 |
7 |
6 |
1.4 |
33.05 |
3 X 50 |
1 X 54.6 |
 2 X 25 |
7 |
8.3 |
1.6 |
7/3.15 |
1.6 |
7 |
6 |
1.4 |
35.65 |
3 X 70 |
1 X 54.6 |
 2 X 25 |
19 |
10 |
1.8 |
7/3.15 |
1.6 |
7 |
6 |
1.4 |
39.85 |
3 X 95 |
1 X 54.6 |
 2 X 25 |
19 |
11.6 |
1.8 |
7/3.15 |
1.6 |
7 |
6 |
1.4 |
43.05 |
3 X 120 |
1 X 54.6 |
 2 X 25 |
19 |
13 |
1.8 |
7/3.15 |
1.6 |
7 |
6 |
1.4 |
45.85 |
3 X 150 |
1 X 54.6 |
 2 X 25 |
19 |
14.6 |
1.8 |
7/3.15 |
1.6 |
7 |
6 |
1.4 |
49.05 |
FACTORY VIEW |
 |
 |
 |
 |
 |



|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
SABS approved Aerial Bundled ABC Cable for Overhead Use Power Cable
1. Applications
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.
2. Construction
Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand Aac, ACSR, or 6201 alloy neutral messenger.
3. Standards
ASTM B-230, B-231, B-232 and B-399, ICEA S-76-474
4. The Diagram of Structure:
NOTE: Designated Sized are ACSR 6/1 Diameter Equivalent Resistivity Per ASTM-B-399 for 6201.
Conductor temperature of 75° C; Ambient temperatures of 40° C; Emissivity 0.9; 2ft/sec. Wind in sun. Packaging: Available in 500ft coils and in long lengths on reels.
The data is approximate and subject to normal manufacturing tolerances.
To determine current ampacity by conductor size, please consult The National Electric Code, latest edition
Specification:
(1)Self-supporting |
 |
 |
 |
Phase |
Phase |
Phase |
Approx.Overall Diameter |
Min.Bending Radius |
Max. D.C. Resistance of Conductor at 20 |
 |
 |
 |
AAC+UV-XLPE |
Compact Conductor |
UV-XLPE Insulation |
 |
 |
 |
No.X Normal Cross Section of Cores |
No.of Al Wires |
Overall Diameter |
Thickness |
Min. |
Diameter |
 |
 |
 |
No. X mm 2 |
- |
mm |
mm |
mm |
mm |
mm |
kN |
ohm/km |
 |
 |
 |
4 X 16 |
7 |
4.8 |
1.2 |
0.98 |
7.2 |
17.42 |
2.07 |
1.91 |
 |
 |
 |
4 X 25 |
7 |
6 |
1.4 |
1.16 |
8.8 |
21.3 |
3.3 |
1.2 |
 |
 |
 |
4 X 35 |
7 |
7 |
1.6 |
1.34 |
10.2 |
24.68 |
4.5 |
0.868 |
 |
 |
 |
4 X 50 |
7 |
8.3 |
1.6 |
1.34 |
11.5 |
27.83 |
6.2 |
0.641 |
 |
 |
 |
4 X 70 |
19 |
10 |
1.8 |
1.52 |
13.6 |
32.91 |
8.9 |
0.443 |
 |
 |
 |
4 X 95 |
19 |
11.6 |
1.8 |
1.52 |
15.2 |
36.78 |
12.3 |
0.32 |
 |
 |
 |
4 X 120 |
19 |
13 |
1.8 |
1.52 |
16.6 |
40.17 |
15.6 |
0.253 |
 |
 |
 |
4 X 150 |
19 |
14.6 |
1.8 |
1.52 |
18.2 |
44.04 |
19.2 |
0.206 |
 |
 |
 |
3 X 16 |
7 |
4.8 |
1.2 |
0.98 |
7.2 |
15.55 |
2.07 |
1.91 |
 |
 |
 |
3 X 25 |
7 |
6 |
1.4 |
1.16 |
8.8 |
19.01 |
3.3 |
1.2 |
 |
 |
 |
3 X 35 |
7 |
7 |
1.6 |
1.34 |
10.2 |
22.03 |
4.5 |
0.868 |
 |
 |
 |
3 X 50 |
7 |
8.3 |
1.6 |
1.34 |
11.5 |
24.84 |
6.2 |
0.641 |
 |
 |
 |
3 X 70 |
19 |
10 |
1.8 |
1.52 |
13.6 |
29.38 |
8.9 |
0.443 |
 |
 |
 |
3 X 95 |
19 |
11.6 |
1.8 |
1.52 |
15.2 |
32.83 |
12.3 |
0.32 |
 |
 |
 |
3 X 120 |
19 |
13 |
1.8 |
1.52 |
16.6 |
35.86 |
15.6 |
0.253 |
 |
 |
 |
3 X 150 |
19 |
14.6 |
1.8 |
1.52 |
18.2 |
39.31 |
19.2 |
0.206 |
 |
 |
 |
2 X 16 |
7 |
4.8 |
1.2 |
0.98 |
7.2 |
14.4 |
2.07 |
1.91 |
 |
 |
 |
2 X 25 |
7 |
6 |
1.4 |
1.16 |
8.8 |
17.6 |
3.3 |
1.2 |
 |
 |
 |
2 X 35 |
7 |
7 |
1.6 |
1.34 |
10.2 |
20.4 |
4.5 |
0.868 |
 |
 |
 |
2 X 50 |
7 |
8.3 |
1.6 |
1.34 |
11.5 |
23 |
6.2 |
0.641 |
 |
 |
 |
2 X 70 |
19 |
10 |
1.8 |
1.52 |
13.6 |
27.2 |
8.9 |
0.443 |
 |
 |
 |
2 X 95 |
19 |
11.6 |
1.8 |
1.52 |
15.2 |
30.4 |
12.3 |
0.32 |
 |
 |
 |
2 X 120 |
19 |
13 |
1.8 |
1.52 |
16.6 |
33.2 |
15.6 |
0.253 |
 |
 |
 |
2 X 150 |
19 |
14.6 |
1.8 |
1.52 |
18.2 |
36.4 |
19.2 |
0.206 |
 |
 |
 |
1 X 16 |
7 |
4.8 |
1.2 |
0.98 |
7.2 |
7.2 |
2.07 |
1.91 |
 |
 |
 |
1 X 25 |
7 |
6 |
1.4 |
1.16 |
8.8 |
8.8 |
3.3 |
1.2 |
 |
 |
 |
1 X 35 |
7 |
7 |
1.6 |
1.34 |
10.2 |
10.2 |
4.5 |
0.868 |
 |
 |
 |
1 X 50 |
7 |
8.3 |
1.6 |
1.34 |
11.5 |
11.5 |
6.2 |
0.641 |
 |
 |
 |
1 X 70 |
19 |
10 |
1.8 |
1.52 |
13.6 |
13.6 |
8.9 |
0.443 |
 |
 |
 |
1 X 95 |
19 |
11.6 |
1.8 |
1.52 |
15.2 |
15.2 |
12.3 |
0.32 |
 |
 |
 |
1 X 120 |
19 |
13.01 |
1.8 |
1.52 |
16.6 |
16.6 |
15.6 |
0.253 |
 |
 |
 |
1 X 150 |
19 |
14.6 |
1.8 |
1.52 |
18.2 |
18.2 |
19.2 |
0.206 |
 |
 |
 |
(2) Phase + Supporting |
 |
 |
 |
Phase |
Supporting |
Phase |
Supporting |
Approx. Overall Diameter |
 |
 |
 |
 |
AAC+UV-XLPE |
AAAC+UV-XLPE |
Compact Conductor |
UV-XLPE Insulation |
Conductor |
UV-XLPE Insulation |
 |
 |
 |
 |
No.X Normal Cross Section of Cores |
No.X Normal Cross Section of Cores |
No.of Al Wires |
Overall Diameter |
Normal Thickness |
No./Dia.of Al. Wire |
Normal Thickness |
 |
 |
 |
 |
No. X mm 2 |
No. X mm 2 |
- |
mm |
mm |
No./mm |
mm |
mm |
 |
 |
 |
 |
3 X 16 |
1 X 54.6 |
7 |
4.8 |
1.2 |
7/3.15 |
1.6 |
20.72 |
 |
 |
 |
 |
3 X 25 |
1 X 54.6 |
7 |
6 |
1.4 |
7/3.15 |
1.6 |
23.63 |
 |
 |
 |
 |
3 X 35 |
1 X 54.6 |
7 |
7 |
1.6 |
7/3.15 |
1.6 |
26.17 |
 |
 |
 |
 |
3 X 50 |
1 X 54.6 |
7 |
8.3 |
1.6 |
7/3.15 |
1.6 |
28.53 |
 |
 |
 |
 |
3 X 70 |
1 X 54.6 |
19 |
10 |
1.8 |
7/3.15 |
1.6 |
32.34 |
 |
 |
 |
 |
3 X 95 |
1 X 54.6 |
19 |
11.6 |
1.8 |
7/3.15 |
1.6 |
35.24 |
 |
 |
 |
 |
3 X 120 |
1 X 54.6 |
19 |
13 |
1.8 |
7/3.15 |
1.6 |
37.78 |
 |
 |
 |
 |
3 X 150 |
1 X 54.6 |
19 |
14.6 |
1.8 |
7/3.15 |
1.6 |
40.69 |
 |
 |
 |
 |
3 X 16 |
1 X 70 |
7 |
4.8 |
1.2 |
7/3.5 |
1.6 |
21.36 |
 |
 |
 |
 |
3 X 25 |
1 X 70 |
7 |
6 |
1.4 |
7/3.5 |
1.6 |
24.26 |
 |
 |
 |
 |
3 X 35 |
1 X 70 |
7 |
7 |
1.6 |
7/3.5 |
1.6 |
26.8 |
 |
 |
 |
 |
3 X 50 |
1 X 70 |
7 |
8.3 |
1.6 |
7/3.5 |
1.6 |
29.16 |
 |
 |
 |
 |
3 X 70 |
1 X 70 |
19 |
10 |
1.8 |
7/3.5 |
1.6 |
32.97 |
 |
 |
 |
 |
3 X 95 |
1 X 70 |
19 |
11.6 |
1.8 |
7/3.5 |
1.6 |
35.88 |
 |
 |
 |
 |
3 X 120 |
1 X 70 |
19 |
13 |
1.8 |
7/3.5 |
1.6 |
38.42 |
 |
 |
 |
 |
3 X 150 |
1 X 70 |
19 |
14.6 |
1.8 |
7/3.5 |
1.6 |
41.32 |
 |
 |
 |
 |
3) Phase+Supporting+ Service Connection |
 |
 |
 |
 |
Phase |
Supporting |
Service Connection |
Phase |
   Supporting |
Service Connection |
Approx.Overall Diameter of Bundled Cable |
AAC+UV-XLPE |
AAAC+UV-XLPE |
AAC+UV-XLPE |
Compact Conductor |
UV-XLPE |
Conductor |
UV-XLPE |
Compact Conductor |
UV-XLPE |
No.X Normal Cross Section of Cores |
No.X Normal Cross Section of Cores |
No.X Normal Cross Section of Cores |
No.of Al.Wire |
Overall Dia. |
Normal |
No./Dia.of Al. Wire |
Normal |
No. of Al. Wire |
Overall Dia. |
Normal |
Thickness |
Thickness |
Thickness |
No. X mm 2 |
No. X mm 2 |
No. X mm 2 |
- |
mm |
mm |
No./mm |
mm |
- |
mm |
mm |
mm |
3 X 16 |
1 X 54.6 |
1 X 25 |
7 |
4.8 |
1.2 |
7/3.15 |
1.6 |
7 |
6 |
1.4 |
27.05 |
3 X 25 |
1 X 54.6 |
1 X 25 |
7 |
6 |
1.4 |
7/3.15 |
1.6 |
7 |
6 |
1.4 |
30.25 |
3 X 35 |
1 X 54.6 |
1 X 25 |
7 |
7 |
1.6 |
7/3.15 |
1.6 |
7 |
6 |
1.4 |
33.05 |
3 X 50 |
1 X 54.6 |
1 X 25 |
7 |
8.3 |
1.6 |
7/3.15 |
1.6 |
7 |
6 |
1.4 |
35.65 |
3 X 70 |
1 X 54.6 |
1 X 25 |
19 |
10 |
1.8 |
7/3.15 |
1.6 |
7 |
6 |
1.4 |
39.85 |
3 X 95 |
1 X 54.6 |
1 X 25 |
19 |
11.6 |
1.8 |
7/3.15 |
1.6 |
7 |
6 |
1.4 |
43.05 |
3 X 120 |
1 X 54.6 |
1 X 25 |
19 |
13 |
1.8 |
7/3.15 |
1.6 |
7 |
6 |
1.4 |
45.85 |
3 X 150 |
1 X 54.6 |
1 X 25 |
19 |
14.6 |
1.8 |
7/3.15 |
1.6 |
7 |
6 |
1.4 |
49.05 |
3 X 16 |
1 X 54.6 |
 2 X 25 |
7 |
4.8 |
1.2 |
7/3.15 |
1.6 |
7 |
6 |
1.4 |
27.05 |
3 X 25 |
1 X 54.6 |
 2 X 25 |
7 |
6 |
1.4 |
7/3.15 |
1.6 |
7 |
6 |
1.4 |
30.25 |
3 X 35 |
1 X 54.6 |
 2 X 25 |
7 |
7 |
1.6 |
7/3.15 |
1.6 |
7 |
6 |
1.4 |
33.05 |
3 X 50 |
1 X 54.6 |
 2 X 25 |
7 |
8.3 |
1.6 |
7/3.15 |
1.6 |
7 |
6 |
1.4 |
35.65 |
3 X 70 |
1 X 54.6 |
 2 X 25 |
19 |
10 |
1.8 |
7/3.15 |
1.6 |
7 |
6 |
1.4 |
39.85 |
3 X 95 |
1 X 54.6 |
 2 X 25 |
19 |
11.6 |
1.8 |
7/3.15 |
1.6 |
7 |
6 |
1.4 |
43.05 |
3 X 120 |
1 X 54.6 |
 2 X 25 |
19 |
13 |
1.8 |
7/3.15 |
1.6 |
7 |
6 |
1.4 |
45.85 |
3 X 150 |
1 X 54.6 |
 2 X 25 |
19 |
14.6 |
1.8 |
7/3.15 |
1.6 |
7 |
6 |
1.4 |
49.05 |
FACTORY VIEW |
 |
 |
 |
 |
 |



|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |