With the advancement of industrial automation, the use of sensors in various industries has become increasingly widespread. Among these, thermocouples are one of the most commonly used temperature-sensing devices. They operate based on the thermoelectric effect and are essential for accurate temperature measurement. However, during practical applications, thermocouples can often be affected by interference, which may lead to inaccurate readings. Therefore, it's crucial to understand and implement effective measures to prevent such disturbances.
One of the key methods is isolation. This involves suspending the thermocouple so that it does not come into direct contact with the refractory materials of the furnace wall. Additionally, an insulator should be placed between the thermocouple and its supporting bracket to minimize thermal leakage interference. Another approach is shielding. By enclosing the thermocouple’s compensation wires in a metal conduit like an iron pipe, electromagnetic and high-voltage electric field interferences can be significantly reduced. It's important to ensure that the shield is properly grounded and that the wires are twisted for better protection.
Grounding is another effective technique. It involves grounding the measuring circuit to divert any unwanted interference into the earth, thus maintaining measurement accuracy. There are two common grounding methods: grounding the reference junction or the measuring junction. For reference grounding, one end of the thermocouple’s output (or compensation wire) is connected to ground through a large capacitor. In the case of measuring junction grounding, a wire is directly connected from the thermocouple’s measurement point to the ground. When using this method, it's important to use heat-resistant and non-reactive cables to avoid damaging the thermocouple elements.
In addition to these techniques, it's also important to consider other anti-interference strategies when working with thermocouples. Avoid placing them near strong magnetic fields, and use shielded cables for both power and signal lines. Separating wiring and keeping a safe distance from other systems can further reduce the risk of interference. In industrial settings, where various instruments and control systems are interconnected, signals can range from very weak millivolt-level signals to high-voltage, high-current ones. These differences can cause signal distortion due to potential differences between grounding points, creating what is known as a "ground loop."
A ground loop can lead to system instability or even incorrect operation. To address this issue, three main solutions are typically considered. The first is signal isolation, which breaks the loop without affecting the normal transmission of the signal. The second is to ensure all field devices are grounded at only one point, preventing the formation of a loop. However, this can be challenging in practice since some equipment requires grounding for safety or accuracy. The third solution involves equalizing the potentials of the two grounding points, but this is difficult to achieve consistently due to factors like soil conditions and weather changes.
By implementing these measures, thermocouple measurements can become more reliable, leading to improved efficiency and accuracy in industrial processes. Understanding and addressing interference issues is essential for ensuring the proper functioning of automated systems and maintaining consistent performance in real-world applications.